gwinstek>>Gwinstek>>GSP-9330
GSP-9330 Specification |
|
Frequency |
|
Frequency Range |
9 kHz to 3.25 GHz |
Frequency Reference |
|
Accuracy |
±[(period since last adjustment X aging rate) + stability over temperature + supply voltage stability |
Frequency Readout Accuracy |
|
Start, Stop, Center, Marker |
±(marker frequency indication X frequency reference accuracy + 10% x RBW + frequency resolution) |
Marker Frequency Counter |
|
Resolution |
1 Hz, 10 Hz, 100 Hz, 1 kHz |
Frequency Span |
|
Range |
0 Hz (zero span), 100 Hz to 3.25 GHz |
Phase Noise |
|
Offset from Carrier |
Fc =1 GHz; RBW = 1 kHz, VBW = 10 Hz;Average ≥ 40 |
Resolution Bandwidth (RBW) Filter |
|
Filter Bandwidth |
1 Hz to 1 MHz in 1-3-10 sequence ; -3dB bandwidth |
Video Bandwidth (VBW) Filter |
|
Filter Bandwidth |
1 Hz to 1 MHz in 1-3-10 sequence ; -3dB bandwidth |
Amplitude Range |
|
Measurement Range |
100 kHz to 1 MHz ; Displayed Average Noise Level (DANL) to 18 dBm |
Attenuator |
|
Input Attenuator Range |
0 to 50 dB, in 1 dB step ; Auto or manual setup |
Maximum Safe Input Level |
|
Average Total Power |
≤ +33 dBm ; Input attenuator ≥10 dB |
1 dB Gain Compression |
|
Total Power at 1st Mixer |
> 0 dBm ; Typical, Fc ≥50 MHz, preamp. off |
Displayed Average Noise Level (DANL)4 |
|
Preamp off |
0 dB attenuation; RF Input is terminated with a 50 ohm load. RBW 10 Hz; VBW 10 Hz; span 500 Hz; reference level = -60dBm; trace average ≥ 40 |
Level Display Range |
|
Scales |
Log, Linear |
Absolute Amplitude Accuracy |
|
Absolute Point |
Center=160 MHz ; RBW 10 kHz; VBW 1 kHz; span 100 kHz; log scale;1 dB/div; peak detector; 23°C±1°C; Signal at Reference Level |
Frequency Response |
|
Preamp off |
Attenuation: 10 dB; Reference: 160 MHz; 20 to 30°C |
Attenuation Switching Uncertainty |
|
Attenuator setting |
0 to 50 dB in 1 dB step |
RBW Filter Switching Uncertainty |
|
1 Hz to 1 MHz |
± 0.25 dB ; reference : 10 kHz RBW |
Level Measurement Uncertainty |
|
Overall Amplitude Accuracy |
± 1.5 dB ; 20 to 30°C; frequency > 1 MHz; Signal input 0 to -50 dBm; |
Spurious Response |
|
Second Harmonic Intercept |
Preamp off; signal input -30dBm; 0 dB attenuation |
Sweep Time |
|
Range |
204 us to 1000 s ; Span > 0Hz |
RF Preamplifier (installed as standard) |
|
Frequency Range |
1 MHz to 3.25 GHz |
RF Input |
|
Connector Type |
N-type female |
Power for Option |
|
Connector Type |
SMB male |
USB Host |
|
Connector Type |
A plug |
MicroSD Socket |
|
Protocol |
SD 1.1 |
Reference Output |
|
Connector Type |
BNC female |
Reference Input |
|
Connector Type |
BNC female |
Alarm Output |
|
Connector Type |
BNC female; Open-collector |
Trigger Input/ Gated Sweep Input |
|
Connector Type |
BNC female |
LAN TCP/IP Interface |
|
Connector Type |
RJ-45 |
USB Device |
|
Connector Type |
B plug ; For remote control only; supports USB TMC |
IF Output |
|
Connector Type |
SMA female |
Earphone Output |
|
Connector Type |
3.5mm stereo jack, wired for mono operation |
Video Output |
|
Connector Type |
DVI-I ( integrated analog and digital) , Single Link ; Compatible with VGA or HDMI standard through adapter |
RS232 Interface |
|
Connector Type |
D-sub 9-pin female ; Tx,Rx,RTS,CTS |
GPIB Interface (Optional) |
|
Connector Type |
IEEE-488 bus connector |
AC Power Input |
|
Power Source |
AC 100 V to 240 V, 50 / 60 Hz ; Auto range selection |
Battery Pack (Optional) |
|
Battery pack |
6 cells, Li-Ion rechargeable, 3S2P ; With UN38.3 Certification |
General |
|
Internal Data storage |
16 MB nominal |
Tracking Generator (Optional) |
|
Frequency Range |
100 kHz to 3.25 GHz |