모델명
|
PSB-1400L
|
PSB-1400M
|
PSB-1800L
|
PSB-1800M
|
소비자가격 (VAT 별도)
|
견적 문의
|
견적 문의
|
견적 문의
|
견적 문의
|
채널
|
1CH
|
정격 전압
|
0~40V
|
0~160V
|
0~40V
|
0~160V
|
정격 전류
|
0~40A
|
0~10A
|
0~80A
|
0~20A
|
정격 전력
|
400W
|
400W
|
800W
|
800W
|
분해능 (PC 프로그래밍)
|
10mV/1mA
|
3mV/1mA
|
1mV/2mA
|
3mV/1mA
|
인터페이스
|
기본 : USB/LAN/Analog IO, 옵션 : GPIB
|
지원 기능
|
정격 출력 내의 멀티-레인지(V&I) 동작, I/V 제어 기능, 슬루율 조정 기능, CV/CC 우선 순위 선택 기능, 직렬 연결 : 최대 2대, 병렬 연결 : 최대 4대, 시퀀스 기능, SYNC 동작 : 전압 트리거, 트리거 입력/출력 신호, 내부 센스 제어 : Disable, Front/Rear Panel
|
|
The PSB-1000 series is equipped with multi range power output capability providing fourfold rated power output to meet customers' flexible application requirements. The models and operating area of the entire series are as the following chart:
Model Name
|
Output Voltage
|
Output Current
|
Output Power
|
PSB-1400L
|
40V
|
40A
|
400W
|
PSB-1400M
|
160V
|
10A
|
400W
|
PSB-1800L
|
40V
|
80A
|
800W
|
PSB-1800M
|
160V
|
20A
|
800W
|
Operating Area
|
Parallel/Series Operation
|
To augment output power so as to meet customers' large voltage and large current requirements, the PSB-1000 series, via placing two same model units in series connection, will be able to produce twofold rated voltage output, and through connecting four same model units in parallel, the PSB-1000 series can produce fourfold rated current output. The maximum voltage output of 320V can be achieved via placing the PSB-1000 series in series connection, and the maximum current of 320A and the maximum power of 3200W can be obtained through parallel connection.
Parallel Connection
|
1 unit
|
2 units
|
3 units
|
4 units
|
PSB-1400L
|
40V / 40A
|
40V / 80A
|
40V / 120A
|
40V / 160A
|
PSB-1400M
|
160V / 10A
|
160V / 20A
|
160V / 30A
|
160V / 40A
|
PSB-1800L
|
40V / 80A
|
40V / 160A
|
40V / 240A
|
40V / 320A
|
PSB-1800M
|
160V / 20A
|
160V / 40A
|
160V / 60A
|
160V / 80A
|
Series Connection
|
1 unit
|
2 units
|
PSB-1400L
|
40V / 40A
|
80V / 40A
|
PSB-1400M
|
160V / 10A
|
320V / 10A
|
PSB-1800L
|
40V / 80A
|
80V / 80A
|
PSB-1800M
|
160V / 20A
|
320V / 20A
|
|
Power On Configuration
|
The PSB-1000 series provides different Power On Configurations for different users. Users can also set automatic execution procedures to be carried out as soon as power is turned on. After presetting Power On Configuration, each rebooting will have a short activation display to show present settings of Power On Configuration of the PSB-1000 series. The execution will be conducted by the power on mode.
Power On Configuration Parameters Include: 1. CV control settings: Local(master), Ext-V(external voltage control), Ext-R↗, Ext-R↘(external resistance control) 2. CC control settings: Local(master), Ext-V(external voltage control), Ext-R↗, Ext-R↘(external resistance control) 3. PON automatic execution while power on: None (non execution), Output On (automatic output while power is on), SEQ0~SEQ9 (automatic sequence execution while power is on) 4. Track series and parallel settings: Local (master operation), S/Slave (set as Slave under the series connection mode), P/Slave (set as Slave under the parallel connection mode), P2-P4/M (set as Master under the parallel connection mode) 5. Ext-Out external analog output control: set High to indicate pin18-19 open circuit (Open) power output. set Low to indicate pin18-19 short circuit (Short) power output. 6. Breaker: set Enable (while alarm is sounded, PSB-1000 will shut down automatically) set Disable (while alarm is sounded, PSB-1000 will cease outputting) 7. Sense Control set Disable (non activation of internal Remote sense terminal) set Rear (activation of rear panel internal Remote sense terminal) set Front (activation of front panel internal Remote sense terminal)
|
POC setting screen
|
Enable OCP Control
|
The On/Off of the OCP protection function can be selected from the master display screen and the OCP activation time can delay 0.1~2.0 seconds. This function can protect customers' DUTs from over current to avoid unexpected operations which lead to DUT damage caused by over current.
|
Enable OCP Control
|
Voltage Trigger
|
Voltage Trigger allows users to set pulse signals for leading edge threshold Vt1 and trailing edge threshold Vt2. VOLT TRIG can be applied to provide output time for working voltage via BNC adapter. Users can determine positive or negative voltage trigger signals by Tref.
|
Voltage Trigger setting
|
|
Output Delay
|
Power output and on/off facilitate flexible planning and setting with respect to time. • Set On Delays time to delay 0.00 ~ 100.00 seconds for power output • Set Off Delays time to delay 0.00 ~ 100.00 seconds for power off
|
I/V Control
|
CV and CC priority can be set based upon customers' application requirements. The speed of voltage rise (V/s) or voltage fall (V/s), and the speed of current rise (A/s) or current fall (A/s) can be set respectively. The PSB-1000 series provides customers with the following four modes to meet their requirements.
|
CVHS > voltage with maximum speed Slew Rate CCHS > current with maximum speed Slew Rate CVLS > users set voltage Slew Rate CCLS > users set current Slew Rate
|
I/V Control screen
|
Bleeder Circuit Control
|
The PSB-1000 series power supply has a bleeder circuit control which is in parallel with the output terminal. When power is off or load is disconnected, bleed resistor will consume electricity from the filter capacitor. Without a bleed resistor, the filter capacitor of power could still be charged with electricity that poses a potential danger. In addition, for ATE system, bleed resistor allows the PSB-1000 series to bleed current rapidly so as to prepare itself for the next operation.
The PSB-1000 series Bleeder Circuit
|
Average Settings
|
Allow users to decide measurement average to be output based upon the requirements. Under Low level, the real time average can be displayed. On the contrary, under the High level, the higher average will be displayed.
|
Sequence Function
|
There are 10 sets of the Sequence function for customers to determine record settings. Automatically executing sequential waveforms can be done without the PC. For instance, sequential power output simulates the power supply of DUT's aging battery to understand the impact on DUT's characteristics.
|
Analog Programming Connector Function
|
On the rear panel of the PSB-1000 series, a 26-pin analog control terminal is designed to perform remote control and monitoring functions. External voltage or resistor can be utilized to set output voltage and current. The power supply output on/off control and master power shut-down can also be controlled by using the external switch. The analog control terminal is complied with the Mil 26-pin connector (OMRON XG4 IDC plug) standard.
|
|