PRODUCT
고객님께 적합하고 효율적인 최선의 솔루션을 제안하겠습니다.
tektronix>>고전압차동프로브>>THDP0200
Tektronix offers a broad portfolio of high-voltage probing solutions that enable users to safely and accurately make floating measurements.
Key features
-
Overrange Indicator
-
Safety Certified
-
Switchable Attenuation
-
Switchable bandwidth limit
Applications
-
Floating measurements
-
Switching power supply design
-
Motor drive design
-
Electronic ballast design
-
CRT display desingn
-
Power converter desigh and service
-
Power device evaluation
Safe high-voltage probe solutions
The THDP0200 is a active differential probe that are capable of safely measuring differential voltages up to ±1500 V. The probe is effective in making measurements in IGBT circuits such as motor drives and power converters. The THDP0200 supports bandwidths up to 200 MHz and slew rates up to 275 V/ns at 1/250 gain.
Connectivity options
The TMDP and THDP Series probes are equipped with the TekVPI® interface which allows smart communication between the oscilloscope and probe. Pushing the probe menu button will launch the probe control menu on the oscilloscope display providing access to all relevant probe settings and controls. These probes are designed to operate on TekVPI® oscilloscopes without requiring the TPA-BNC adapter.
Specifications
Attenuation |
50X / 500X |
Differential Voltage |
500X : ±1500 V 50X : ±150 V |
Common Mode Voltage |
±1500 V |
Maximum Input Voltage-to-Earth |
1000 V CATⅡ 600 V CATⅢ |
Bandwidth |
200 MHz |
Rise Time |
<1.8 ns |
Slew Rate |
<650 V/ns at 1/500 gain |
Input Impedance at the Probe Tip |
10 MΩ || <2 pF |
Typical CMRR |
DC: > -80 dB |
Cable Length |
1.5 m |